The KOBOLD DMH flowmeter is designed to measure and monitor the volume flow rate of liquids, pulps, pastes, and other electrically conductive media without loss of pressure and can be used in rugged environments. When an electrically conductive media passes through a directional magnetic field, a voltage is induced in accordance with Faraday’s Law of Induction. The measured voltage is proportional to the mean rate of flow and consequently also to the volumetric flow rate. The flowmeter consists of a sensor that picks up the measuring signal generated from the induced voltage, and a transducer that converts this signal into a standardized output signal (4-20mA or pulse). The measuring transducer can be connected to the sensor directly or mounted remotely. Pressure, temperature, density, and viscosity do not affect the volume measurement. Large solids and gas bubbles should be avoided. The DMH offers a variety of lining, electrode, and process connection option